Customization: | Available |
---|---|
Application: | High-voltage |
Material: | Porcelain |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Oufdoorimmersed bushing
Bushing, one end of which is intended to be in ambient air and exposed to outdoor atmospheric conditions and the other end to be immersed in an insulating medium other than ambient air (e.g. oil or gas).
Creepage distance
Shortest distance along the surface of an insulafor between fwo conducfive parts
Minimum nominal creepage distance
Unless otherwise agreed between purchaser and supplier, or demonstrafed by a fest, the creepage distance in accordance with lEC 815 isdetermined by Ur/KVl x dcs /mm/kV)x kD where;Arcing distance
Shortest distance in citr extemal to the insulator between metalic parts which normally have the operating voltage between them.
Altitude
Although the insulafion level refers to sea level, bushings coresponding fo this standard are declared suitable for operafion at any altitude not exceeding 1000 m. in order to ensure hat the external withstand voltages of the bushing are suficient at alitudes exceeding 1000 m, the arcing distance normally required shall be increased by a suitable amount. It is not necessarv to adjust the radial thickness of insulation or the clearance of the immersed end. The puncture strength and the flashover voltage in the immersion medium of a bushing are not affected by altitude.
To the limitations of puncture strength and flashover voltage in the immersion medium it may not always be possible to check the adequacy of the increased arcing distance by actual test at any altitude lower than that of operation. In such a case the supplier shall demonstrate by the amount of increase of the arcing distance, that the bushing is adequate.
For general guidance an increase of 1,0% of the arcing distance necessary at sea level for each 100 m in excess of 1000 m up to a maximum of 3000 m above sea level should be applied.
EXAMPLE Altitude of installation 2800 m;
Increase in arcing distance.
CODE | A50012000 | A50020000 | A50030000 | A50042000 | A50048000 | |||||
CLASS | 1/250 | 1/630 | 1/1000 | 1/2000 | 1/3150 | |||||
Draw. refer | A | B | A | B | A | B | A | B | A | B |
H | 70 | 30 | 80 | 30 | 85 | 35 | 85 | 35 | 85 | 35 |
D | 50 | 60 | 70 | 85 | 90 | 110 | 104 | 125 | 125 | 150 |
d1 | 32 | 30 | 47 | 46 | 65 | 57 | 80 | 70 | 100 | 90 |
d2 | 50 | 50 | 70 | 70 | 90 | 90 | 104 | 104 | 125 | 125 |
d3 | 27 | 26 | 43 | 41 | 53 | 46 | 66 | 64 | 86 | 80 |
d4 | 14 | 22 | 32 | 44 | 50 | |||||
h | 25 | 20 | 25 | 20 | 30 | 25 | 30 | 25 | 30 | 25 |
F | 50 | 70 | 90 | 104 | 125 | |||||
F1 | 20 | 28 | 37 | 51 | 61 | |||||
Creepage distance mm | 50 | 75 | 75 | 75 | 75 | |||||
Arcing distance mm | 50 | 60 | 60 | 60 | 60 | |||||
Rated voltage kV | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
g / Weight (gr.) | 160 | 100 | 380 | 190 | 640 | 400 | 820 | 470 | 1350 | 700 |