Outdoor 35KV 33KV Dyn11 Oil Immersed Hermetically Sealed Distribution Transformer
High overload distribution transformers
Product overview
In recent years, with the increasing mobility of the population, the hot season, and distribution transformers in rural areas during the Spring Festival period of severe overload short run problem of rural electricity appears. In order to solve such problem of electricity, the company response to the State Grid Corporation of China in recent years advocated actively develop rural power distribution transformers and high overload capacity application work, we developed a high overload capacity distribution transformers.
High overload capacity integrated rural power distribution transformer station area based on typical load characteristics, high overload distribution transformer overload performance will meet the 1.5 times the rated capacity of six hours, 1.75 times the rated capacity of 3 hours, 2.0 times the rated capacity of one hour of continuous operation stage design requirements, and does not affect the normal life of the transformer. High overload capacity distribution transformer avoids the migration of rural electricity appeared short period of severe overload, reduce operating costs grid, Improve the safety of power grid operation, which is a major direction for the future selection of rural distribution transformers.
Use of the environment
Service condition
Ambient temperature
Highest air temperature +40ºC
Lowest air temperature -25ºC
Hottest monthly average temperature +30ºC
Hottest yearly average temperature + 20ºC
The height above the sea level is below 1000m;
The power supply voltage's cave is similar to sine wave ;
Three-phase power supply voltage is approximately symmetrical.
S11-M Type 6~10kV
Performance parameters
Rated capacity(KVA) | Voltage Combination and tap range | connection of transformer winding | No-load loss (W) |
Load loss (W) | No-load current (%) | Short circuit impedance (%) | ||
High voltage (KV) |
High voltage tap range ( %) |
Low voltage (KV) |
||||||
50 100 200 |
10 10.5 11 |
±5% ±2x2.5% |
0.4 |
Dyn11 Yyn0 |
130 200 340 |
910/870 1580/1500 2730/2600 |
1.1 1 0.9 |
4 4 4 |
Rated capacity(KVA) | Voltage Combination and tap range | connection of transformer winding | No-load loss (W) |
Load loss (W) | No-load current (%) | Short circuit impedance (%) | ||
High voltage (KV) |
High voltage tap range ( %) |
Low voltage (KV) |
||||||
50 100 200 |
10 10.5 11 |
±5% ±2x2.5% |
0.4 |
Dyn11 Yyn0 |
100 150 240 |
910/870 1580/1500 2730/2600 |
0.8 0.7 0.6 |
4 4 4 |